Shoulder Fracture Solutions

 

 

                   Streamlining your practice

                              from fingertip to clavicle

 

 

 

 

 

 

 

About the S Proximal Humerus Plating System

 

Minimizes Subacromial Impingement

  •The S plate is designed to be positioned approximately 3.0 cm
   distal to the greater tuberosity helping to prevent subacromial
   impingement

Minimizes Varus Collapse

  •The parametric design of the pegs distribute the loads more
   anatomically through the full range of motion by maintaining the
   neck shaft angle of 135º minimizing the risk of varus collapse

Provides Strong and Secure Fixation

  •The proximal end of the S plate has fixed angle locking pegs/
   screw holes. Its parametric design of convergent and divergent
   screw trajectories ensures a consistent spatial distribution of the
   pegs within the entire humeral head. This particular distribution
   provides spatial subchondral support to resist varus forces
   throughout the full range of motion.

  •4.0 mm blunt tipped subchondral support smooth or threaded
   pegs, provide stability while preventing protrusion through the
   articular surface

  •Proximal and distal locking pegs and screws provide a strong
   interface for a stable fixation.

 

 

 

 


 

About the SNP® Proximal Humeral Plating System

 

The SNP® Proximal Humeral Plating System provides the surgeon with an effective, less invasive option for fractures of the proximal humerus. The SNP® combines the proximal stability of fixed angle locking pegs and suture attachments with the minimal soft tissue disruption of an intramedullary nail.

 

 

 

 

 

 

 

 

 

 

About the Global AP Shoulder

 

The Global AP Shoulder Arthoplasty System is the next generation proximal press-fit DePuy Orthopaedics shoulder arthroplasty system that combines advanced engineering and almost 20 years of Global Shoulder clinical success.

  •Collarless design allows for anatomic reconstruction of the
   proximal humerus with two neck options using a single surgical
   technique:

     •Fixed 135º neck angle for simplicity in uncomplicated
      arthroplasty

     •Adjustable (120-150º neck angle and +/– 15º version) for
      enhanced joint stability

  •Titanium alloy in Porocoat® for optimized cementless
   application

  •Low profile standard and eccentric humeral heads

  •Revision long stem lengths up to 220mm

 

 

 

About the Global FX Shoulder

 

Developed specifically for humeral head fractures, DePuy's GLOBAL® FX Shoulder Fracture System includes many features to assist the surgeon with this particularly difficult procedure. One such feature is a unique positioning jig to assist in establishing proper height and version. The GLOBAL® FX System also maintains many of the benefits that continue to make DePuy's GLOBAL® Shoulder Collection the leading shoulder prosthesis in the United States.

 

 

 

About the Global CAP Shoulder

 

This conservative, resurfacing implant is an option for a younger patient population seeking a bone sparing option. The implant is secured by a short, cruciate stem and undersurface Porocoat® porous coating or DuoFix® HA on porous coating. It is intended for patients with degenerative or rheumatoid arthritis.

For complete information visit GLOBAL® AP® OR GLOBAL® FX OR GLOBAL® CAP®

 

1Market share data from Millennium Research Group U.S. Markets for Small-Joint Devices 2009 report (March 2009,
RPUS21SJ09, http://www.mrg.netwww.mrg.net).

 

 

About the Delta Xtend™ System

 

The Delta Xtend™ System is a total, semi-constrained shoulder arthroplasty that reverses the normal relationship between the scapular and humeral components, moving the scapulo-humeral joint center of rotation medially and inferiorly, increasing the deltoid lever arm as well as the deltoid tension and therefore allowing the muscles of the deltoid group to compensate for rotator cuff deficiency5. The Delta Xtend™ humeral stem is designed for cemented fixation. The glenoid component is cementless with four screws as primary fixation and HA coating for secondary fixation. Each design feature has been defined to help achieve the clinical goals for CTA cases with the Delta Xtend Reverse Shoulder System: recovery, function, and survivorship.

For complete information visit Delta XTEND™

 

 

 

About the Humeral Proximal Versanail®

 

Intramedullary fixation of humeral proximal fractures

Nail design to treat simple to complex proximal humeral fractures

Mechanical stability achieved with minimal dissection, for rapid postoperative mobilization

Proprietary locking sleeve system reduces potential for proximal screw back-out

Easy-to-use targeting jig rotates for simplified screw placement and improved visualization

The intuitive, universal instrumentation system enables efficiency in the OR

May 21 2012 - 21:23:01